  vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 110 v fiam, filter input attenuator module rev. 1.0 page 1 of 6 set your site on vicor at vicorpower.com parameter rating unit notes +in to ? in 154 vdc continuous 385 v 20 ms +out to ? out 154 vdc continuous mounting torque 5(0.57) in-lbs 6 each, #4-40 or m3 operating temperature ? 55 to +100 c m -grade storage temperature ? 65 to +125 c m -grade pin soldering temperature 500 (260) f(c) < 5 sec; wave solder 750 (390) f(c) < 7 sec; hand solder features ? rohs compliant (with f or g pin style) ? emi filtering-en50121-3-2 * ? transient protection-en50155, en50121-3-2 ? low profile mounting options ? 500 w output power ? 60950-1 compliance ? mini-size package ? inrush current limiting product highlights the fiam110 is a dc front-end module designed for rail applications providing transient protection, inrush current limiting and emi filtering (en50121-3-2) in a mini-size package. the fiam enables designers using vicor 110 vin mini, micro, or maxi or vi/ve-200 and vi/ve-j00 (t input) dc-dc converters to meet the transient immunity and emi requirements required for the rail industry and protect system hardware from inrush current. the fiam110 accepts an input voltage of 66 ? 154 vdc and provide up to 500 w of output power and remote on/off control. the fiam110 is housed in an industry standard "half brick" module measuring 2.28" x 2.2" x 0.5" and depending upon model selected, may be mounted on-board or in-board for height critical applications. compatible products ? mini, micro, maxi 110 v input dc-dc converters ? vi / ve-200, vi / ve-j00 (?t? input) * emi performance is subject to a wide variety of external influences such as pcb construction, circuit layout etc. as such, external components in addition to those listed herein may be required in specific instances to gain full compliance to the standards specified. data sheet 110 v fiam tm filter input attenuator module shown actual size: 2.28 x 2.2 x 0.5 in 57,9 x 55,9 x 12,7 mm absolute maximum rating parameter min typ max unit baseplate to sink flat, greased surface 0.16 c/watt thermal pad (p/n 20264) 0.14 c/watt baseplate to ambient free convection 8.0 c/watt 1000 lfm 1.9 c/watt thermal resistance part numbering product baseplate 1 = slotted 2 = threaded 3 = thru-hole pin style 1 = short 2 = long s = short modumate n = long modumate f = short rohs g = long rohs product grade temperatures (c) grade operating storage e = ? 10 to +100 ? 20 to 125 c = ? 20 to +100 ? 40 to 125 t = ? 40 to +100 ? 40 to 125 h = ? 40 to +100 ? 55 to 125 m = ? 55 to +100 ? 65 to 125 fiam 110 c 1 1 110 vin nominal www.datasheet.co.kr datasheet pdf - http://www..net/
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 110 v fiam, filter input attenuator module rev. 1.0 page 2 of 6 set your site on vicor at vicorpower.com specifications (typical at t bp = 25c, nominal line and 75% load, unless otherwise specified) input specifications control pin specifications emi parameter min typ max unit notes input voltage 66 110 154 vdc continuous inrush limiting 0.06 a/f transient immunity 176 vdc consistent with 100 ms per nf f 01-510 165 vdc consistent with 1 s per ria 12 385 vdc consistent with 20 ms per ria 12 parameter min typ max unit notes on / off control enable (on) 0.0 1.0 referenced to ?vout disable (off) 3.5 5.0 vdc 100k internal pull-up resistor standard notes en50121-3-2 150 khz to 500 khz - 99 dbv quasi-peak 500 khz to 30 khz - 93 dbv quasi-peak safety?specifications parameter min typ max unit notes dielectric withstand (i/o to baseplate) 1,000 v rms 1,414 vdc immunity parameter typ. value units notes en50121-3-2 (table 7.3 surges) 2,000 vdc waveform ? 1.2 / 50 s, 42 , 0.5 f, line to ground 1,000 vdc waveform ? 1.2 / 50 s, 42 , 0.5 f, line to line performance criteria b - no damage to the product but a temporary change in the intended dc voltage is acceptable as long as it self-recovers without user intervention. en50121-3-2 (table 7.2 fast transients) 2,000 vdc 5/50 ns, 5 khz performance criteria a - no damage to the product and no change to the intended dc voltage level for a duration greater than 1.0 sec. en50121-3-2 (table 7.1 rf common mode) 0.15 to 80 mhz, 10 vrms, 80% am, 1 khz performance criteria a - no damage to the product and no change to the intended dc voltage level greater than +/- 5%. output specifications parameter min typ max unit notes output power 500 w output power derates linearly below 77 vin to 400 w @ 66 vin efficiency 98 % internal voltage drop 2.5 v 500 w at 25c baseplate external capacitance 100 f emi performance is subject to a wide variety of external influences such as pcb construction, circuit layout etc. as such, exte rnal components in addition to those listed herein may be required in specific instances to gain full compliance to the standards specified. www.datasheet.co.kr datasheet pdf - http://www..net/
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 110 v fiam, filter input attenuator module rev. 1.0 page 3 of 6 set your site on vicor at vicorpower.com parameter min typ max unit remarks weight 3.1 4 ounces (88) (113) (grams) warranty 2 years agency?approvals general?specifications specifications (cont.) module environmental qualification altitude mil-std-810f, method 500.4, procedure i & ii, 40,000 ft. and 70,000 ft. operational. explosive atmosphere mil-std-810f, method 511.4, procedure i, operational. vibration en 61373, random vibration: category <0.3kg, freq range: 5-150hz @ 5grms, 5hrs per axis. mil-std-810f, method 514.5, procedure i, category 14, sine and random vibration per table 514.5c for helicopter ah-6j main roto r with overall level of 5.6 g rms for 4 hours per axis. mil-std-810f, method 514.5c, general minimum integrity curve per figure 5 14.5c-17 with overall level of 7.7 g rms for 1 hour per axis. shock en 61373, shock: long. / trans. / vert. axis, peak acceleration: 5g / 2g / 1g, duration: 50 ms/ 20 ms. mil-std-810f, method 516.5, procedure i, functional shock, 40 g. mil-s- 901d, lightweight hammer shock, 3 impacts/axis, 1,3,5 ft. mil-std-202f, method 213b, 60 g, 9 ms half sine. mil-std-202f, method 213b, 75 g, 11 ms saw tooth shock. acceleration mil-std-810f, method 513.5, procedure ii, table 513.5-ii, operational, 2-7 g, 6 directions. humidity mil-std-810f, method 507.4. solder test mil-std-202g, method 208h, 8 hour aging. parameter h-grade m-grade operating temperature -40c to +100c -55c to +100c storage temperature -55c to +125c -65c to +125c temperature cycling* 12 cycles 12 cycles -65c to +100c -65c to +100c ambient test @ 25c yes yes power cycling burn-in 12 hours, 29 cycles 24 hours, 58 cycles functional and parametric ate tests -40c and +100c -55c and +100c hi-pot test yes yes visual inspection yes yes test data vicorpower.com vicorpower.com module environmental stress screening *temperature cycled with power off, 17c per minute rate of change. safety standards markings notes ul60950-1, csa60950-1, en60950-1, iec 60950-1 ctuvus pending en60950-1 ce low voltage directive www.datasheet.co.kr datasheet pdf - http://www..net/
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 110 v fiam, filter input attenuator module rev. 1.0 page 4 of 6 set your site on vicor at vicorpower.com insertion loss transient immunity figure 1 conducted noise (en50121-3-2); fiam110m21 and model v110a24c400bg dc-dc converter operating at 110 vdc, 375 w. figure 2 conducted noise (en50121-3-2); fiam110m21 and model ve-2t3-ew + (3) vi-bt3-iw dc-dc converters operating at 110 vdc, 375 w. figure 3 insertion loss curve. figure 4 transient immunity: fiam output response to an input transient. conducted noise inrush limiting figure 5 inrush current. (100 f external capacitance) www.datasheet.co.kr datasheet pdf - http://www..net/
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 110 v fiam, filter input attenuator module rev. 1.0 page 5 of 6 set your site on vicor at vicorpower.com +s +out sc ?s ?out ?in pr pc +in note: the fiam is shown in the on state. to disable, open the connection between on/off and ?out. transorb p/n 30234-120 fiam110 ?in emi gnd nc +in +out gate in gate out on off ?out f1 0.2 f input c1 4,700 pf 4,700 pf 0.01 f 0.01 f mini, maxi, micro 110 vdc input dc-dc converter or vi / ve-200 or vi / ve-j00 t input dc-dc converter c1=tbd f1=12 a bussmann abc ? 12 or equivalent ul listed fuse. transient and surge protection pcb mounting specifications converter pins no. function label 1+in + 2 no nc connection 3 ground emi/gnd 4?in ? 5?out ? 6 on/off on/off 7 no nc connection 8 no nc connection 9+out + 0.195 4,95 1.400* 35,56 1.000* 25,40 0.700* 17,78 0.400* 10,16 1.790** 45,47 0.06 1,5 r (4x) 0.158 4,01 5 6 7 8 9 12 34 0.003 0,08 * denotes tol = pcb thickness 0.062 0.010 1,57 0,25 short pin style 0.094 0.003 2,39 0,08 inboard solder mount 0.43 10,9 0.53 13,5 1.900* 48.26 1.900* 48,26 1.575** 40,00 0.164 0.003 4,16 0,08 long pin style 0.094 0.003 2,39 0,08 onboard solder mount 0.164 0.003 4,16 0,08 plated through hole dia (7x) (2x) ** pcb window mechanical diagram figure 6 typical connection diagram a maing s thi s s urface pins styles s older:tin / lead plated modumate: gold plated copper roh s : gold plated copper aluminum ba s eplate consult vicor application note: soldering methods and procedures for 1st and 2nd generation modules. www.datasheet.co.kr datasheet pdf - http://www..net/
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 110 v fiam, filter input attenuator module rev. 1.0 1/2012 set your site on vicor at vicorpower.com vicor corporation 25 frontage road andover, ma, usa 01810 tel: 800-735-6200 fax: 978-475-6715 email customer service: custserv@vicorpower.com technical support: apps@vicorpower.com vicors comprehensive line of power solutions includes high density ac-dc and dc-dc modules and accessory components, fully configurable ac-dc and dc-dc power supplies, and complete custom power systems. information furnished by vicor is believed to be accurate and reliable. however, no responsibility is assumed by vicor for its use. vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. all sales are subject to vicor?s terms and conditions of sale, which are available upon request. specifications are subject to change without notice. intellectual property notice vicor and its subsidiaries own intellectual property (including issued u.s. and foreign patents and pending patent applications) relating to the products described in this data sheet. interested parties should contact vicor's intellectual property department. warranty vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. this warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. vicor shall not be liable for collateral or consequential damage. this warranty is extended to the original purchaser only. except for the foregoing express warranty, vicor makes no warranty, express or implied, including, but not limited to, the warranty of merchantability or fitness for a particular purpose. vicor will repair or replace defective products in accordance with its own best judgement. for service under this warranty, the buyer must contact vicor to obtain a return material authorization (rma) number and shipping instructions. products returned without prior authorization will be returned to the buyer. the buyer will pay all charges incurred in returning the product to the factory. vicor will pay all reshipment charges if the product was defective within the terms of this warranty. information published by vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. vicor reserves the right to make changes to any products without further notice to improve reliabilit y, function, or design. vicor does not assume any liability arising out of the application or use of any product or circuit; neith er does it convey any license under its patent rights nor the rights of others. vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. per vicor terms and conditions of sale, the user of vicor components in life support applications assumes all risks of such use and indemnifies vicor against all damages. www.datasheet.co.kr datasheet pdf - http://www..net/


▲Up To Search▲   

 
Price & Availability of FIAM110CG1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X